Agent skill
parameter-optimization
Explore and optimize simulation parameters via design of experiments (DOE), sensitivity analysis, and optimizer selection. Use for calibration, uncertainty studies, parameter sweeps, LHS sampling, Sobol analysis, surrogate modeling, or Bayesian optimization setup.
Install this agent skill to your Project
npx add-skill https://github.com/FreedomIntelligence/OpenClaw-Medical-Skills/tree/main/skills/parameter-optimization
SKILL.md
Parameter Optimization
Goal
Provide a workflow to design experiments, rank parameter influence, and select optimization strategies for materials simulation calibration.
Requirements
- Python 3.8+
- No external dependencies (uses Python standard library only)
Inputs to Gather
Before running any scripts, collect from the user:
| Input | Description | Example |
|---|---|---|
| Parameter bounds | Min/max for each parameter with units | kappa: [0.1, 10.0] W/mK |
| Evaluation budget | Max number of simulations allowed | 50 runs |
| Noise level | Stochasticity of simulation outputs | low, medium, high |
| Constraints | Feasibility rules or forbidden regions | kappa + mobility < 5 |
Decision Guidance
Choosing a DOE Method
Is dimension <= 3 AND full coverage needed?
├── YES → Use factorial
└── NO → Is sensitivity analysis the goal?
├── YES → Use quasi-random (preferred; "sobol" is accepted but deprecated)
└── NO → Use lhs (Latin Hypercube)
| Method | Best For | Avoid When |
|---|---|---|
lhs |
General exploration, moderate dimensions (3-20) | Need exact grid coverage |
sobol |
Sensitivity analysis, uniform coverage | Very high dimensions (>20) |
factorial |
Low dimension (<4), need all corners | High dimension (exponential growth) |
Choosing an Optimizer
Is dimension <= 5 AND budget <= 100?
├── YES → Bayesian Optimization
└── NO → Is dimension <= 20?
├── YES → CMA-ES
└── NO → Random Search with screening
| Noise Level | Recommendation |
|---|---|
| Low | Gradient-based if derivatives available, else Bayesian Optimization |
| Medium | Bayesian Optimization with noise model |
| High | Evolutionary algorithms or robust Bayesian Optimization |
Script Outputs (JSON Fields)
| Script | Output Fields |
|---|---|
scripts/doe_generator.py |
samples, method, coverage |
scripts/optimizer_selector.py |
recommended, expected_evals, notes |
scripts/sensitivity_summary.py |
ranking, notes |
scripts/surrogate_builder.py |
model_type, metrics, notes |
Workflow
- Generate DOE with
scripts/doe_generator.py - Run simulations at DOE sample points (user's responsibility)
- Summarize sensitivity with
scripts/sensitivity_summary.py - Choose optimizer using
scripts/optimizer_selector.py - (Optional) Fit surrogate with
scripts/surrogate_builder.py
CLI Examples
# Generate 20 LHS samples for 3 parameters
python3 scripts/doe_generator.py --params 3 --budget 20 --method lhs --json
# Rank parameters by sensitivity scores
python3 scripts/sensitivity_summary.py --scores 0.2,0.5,0.3 --names kappa,mobility,W --json
# Get optimizer recommendation for 3D problem with 50 eval budget
python3 scripts/optimizer_selector.py --dim 3 --budget 50 --noise low --json
# Build surrogate model from simulation data
python3 scripts/surrogate_builder.py --x 0,1,2 --y 10,12,15 --model rbf --json
Conversational Workflow Example
User: I need to calibrate thermal conductivity and diffusivity for my FEM simulation. I can run about 30 simulations.
Agent workflow:
- Identify 2 parameters →
--params 2 - Budget is 30 →
--budget 30 - Use LHS for general exploration:
bash
python3 scripts/doe_generator.py --params 2 --budget 30 --method lhs --json - After user runs simulations and provides outputs, summarize sensitivity:
bash
python3 scripts/sensitivity_summary.py --scores 0.7,0.3 --names conductivity,diffusivity --json - Recommend optimizer:
bash
python3 scripts/optimizer_selector.py --dim 2 --budget 30 --noise low --json
Error Handling
| Error | Cause | Resolution |
|---|---|---|
params must be positive |
Zero or negative dimension | Ask user for valid parameter count |
budget must be positive |
Zero or negative budget | Ask user for realistic simulation budget |
method must be lhs, sobol, or factorial |
Invalid method | Use decision guidance to pick valid method |
scores must be comma-separated |
Malformed input | Reformat as 0.1,0.2,0.3 |
Limitations
- Not for real-time optimization: Scripts provide recommendations, not live optimization loops
- Surrogate is a placeholder:
surrogate_builder.pycomputes basic metrics; replace with actual model for production - No automatic simulation execution: User must run simulations externally and provide results
References
references/doe_methods.md- Detailed DOE method comparisonreferences/optimizer_selection.md- Optimizer algorithm detailsreferences/sensitivity_guidelines.md- Sensitivity analysis interpretationreferences/surrogate_guidelines.md- Surrogate model selection
Version History
- v1.1.0 (2024-12-24): Enhanced documentation, decision guidance, conversational examples
- v1.0.0: Initial release with core scripts
Recommended Agent Skills
Expand your agent's capabilities with these related and highly-rated skills.
vcf-annotator
Annotate VCF variants with VEP, ClinVar, gnomAD frequencies, and ancestry-aware context. Generates prioritised variant reports.
chemist-analyst
Analyzes events through chemistry lens using molecular structure, reaction mechanisms, thermodynamics, kinetics, and analytical techniques (spectroscopy, chromatography, mass spectrometry). Provides insights on chemical processes, material properties, reaction pathways, synthesis, and analytical methods. Use when: Chemical reactions, material analysis, synthesis planning, process optimization, environmental chemistry. Evaluates: Molecular structure, reaction mechanisms, yield, selectivity, safety, environmental impact.
bio-alignment-io
Read, write, and convert multiple sequence alignment files using Biopython Bio.AlignIO. Supports Clustal, PHYLIP, Stockholm, FASTA, Nexus, and other alignment formats for phylogenetics and conservation analysis. Use when reading, writing, or converting alignment file formats.
sleep-analyzer
分析睡眠数据、识别睡眠模式、评估睡眠质量,并提供个性化睡眠改善建议。支持与其他健康数据的关联分析。
metabolomics-workbench-database
Access NIH Metabolomics Workbench via REST API (4,200+ studies). Query metabolites, RefMet nomenclature, MS/NMR data, m/z searches, study metadata, for metabolomics and biomarker discovery.
bio-hi-c-analysis-matrix-operations
Balance, normalize, and transform Hi-C contact matrices using cooler and cooltools. Apply iterative correction (ICE), compute expected values, and generate observed/expected matrices. Use when normalizing or transforming Hi-C matrices.
Didn't find tool you were looking for?