Agent skill

heat-exchanger-design

Specialized skill for heat exchanger sizing, rating, and optimization per TEMA standards including shell-and-tube, plate, and air-cooled configurations

Stars 514
Forks 31

Install this agent skill to your Project

npx add-skill https://github.com/a5c-ai/babysitter/tree/main/library/specializations/domains/science/mechanical-engineering/skills/heat-exchanger-design

Metadata

Additional technical details for this skill

phase
6
domain
science
category
thermal-fluid-analysis
priority
high
specialization
mechanical-engineering
tools libraries
[
    "HTRI Xchanger Suite",
    "Aspen Exchanger Design and Rating"
]

SKILL.md

Heat Exchanger Design Skill

Purpose

The Heat Exchanger Design skill provides comprehensive capabilities for sizing, rating, and optimizing heat exchangers according to TEMA standards, enabling systematic thermal-hydraulic design of shell-and-tube, plate, and air-cooled heat exchanger configurations.

Capabilities

  • Shell-and-tube heat exchanger design and rating
  • Plate heat exchanger sizing
  • Air-cooled heat exchanger configuration
  • LMTD and effectiveness-NTU methods
  • Fouling factor consideration
  • Pressure drop calculations
  • HTRI Xchanger Suite integration
  • Thermal-hydraulic optimization

Usage Guidelines

Design Methods

LMTD Method

  1. Log Mean Temperature Difference

    LMTD = (ΔT1 - ΔT2) / ln(ΔT1/ΔT2)
    
    Q = U × A × F × LMTD
    
    Where:
    F = Correction factor for non-counterflow
    U = Overall heat transfer coefficient
    A = Heat transfer area
    
  2. LMTD Correction Factors

    • One shell pass, 2/4/6 tube passes
    • Two shell passes, 4/8 tube passes
    • Crossflow configurations

Effectiveness-NTU Method

  1. Effectiveness Definition

    ε = Q_actual / Q_max
    Q_max = Cmin × (Th,in - Tc,in)
    
  2. NTU Calculation

    NTU = UA / Cmin
    Cr = Cmin / Cmax
    
  3. Effectiveness Relations

    • Counterflow: ε = (1-exp(-NTU(1-Cr)))/(1-Cr×exp(-NTU(1-Cr)))
    • Parallel flow: ε = (1-exp(-NTU(1+Cr)))/(1+Cr)
    • Shell-and-tube: Complex correlations by TEMA type

Shell-and-Tube Design

  1. TEMA Designations

    Front End Shell Rear End
    A - Channel E - One-pass L - Fixed tubesheet
    B - Bonnet F - Two-pass M - Fixed tubesheet
    N - Channel J - Divided flow N - Fixed tubesheet
    - X - Crossflow P - Outside packed
    - - S - Floating head
    - - U - U-tube
  2. Tube Layout

    • Triangular pitch (30°): Maximum tubes, poor cleaning
    • Square pitch (90°): Mechanical cleaning possible
    • Rotated square (45°): Higher turbulence
  3. Baffle Design

    • Segmental: 20-45% cut
    • Double segmental: Reduced pressure drop
    • No-tubes-in-window: Vibration mitigation

Plate Heat Exchanger

  1. Plate Selection

    • Chevron angle (25-65°): Trade-off h vs ΔP
    • Plate spacing: 2-5 mm typical
    • Pass arrangement: U or Z configuration
  2. Design Considerations

    • Maximum pressure: 25-30 bar typical
    • Maximum temperature: 150-200°C (gaskets)
    • Fouling service: Not ideal

Air-Cooled Heat Exchanger

  1. Configuration

    • Forced draft: Fan below bundle
    • Induced draft: Fan above bundle
    • Natural draft: No fan (limited duty)
  2. Design Parameters

    • Face velocity: 2.5-3.5 m/s
    • Tube rows: 3-6 typical
    • Fin density: 275-435 fins/m

Fouling Considerations

Service Fouling Factor (m²K/kW)
Cooling water 0.2-0.35
River water 0.35-0.5
Fuel oil 0.5-0.9
Heavy hydrocarbons 0.35-0.7
Light hydrocarbons 0.1-0.2
Steam (clean) 0.05-0.1

Process Integration

  • ME-012: Heat Exchanger Design and Rating
  • ME-011: Thermal Management Design

Input Schema

json
{
  "design_type": "sizing|rating",
  "exchanger_type": "shell_tube|plate|air_cooled",
  "hot_fluid": {
    "name": "string",
    "flow_rate": "number (kg/s)",
    "inlet_temp": "number (C)",
    "outlet_temp": "number (C, for sizing)"
  },
  "cold_fluid": {
    "name": "string",
    "flow_rate": "number (kg/s)",
    "inlet_temp": "number (C)",
    "outlet_temp": "number (C, for sizing)"
  },
  "pressure_constraints": {
    "hot_side_max_dp": "number (kPa)",
    "cold_side_max_dp": "number (kPa)"
  },
  "fouling_factors": {
    "hot_side": "number (m2K/kW)",
    "cold_side": "number (m2K/kW)"
  }
}

Output Schema

json
{
  "duty": "number (kW)",
  "geometry": {
    "type": "string (TEMA designation or plate type)",
    "area": "number (m2)",
    "shell_diameter": "number (mm)",
    "tube_count": "number",
    "tube_length": "number (m)"
  },
  "thermal": {
    "LMTD": "number (C)",
    "F_factor": "number",
    "U_clean": "number (W/m2K)",
    "U_dirty": "number (W/m2K)"
  },
  "hydraulic": {
    "shell_side_dp": "number (kPa)",
    "tube_side_dp": "number (kPa)"
  },
  "performance": {
    "effectiveness": "number",
    "NTU": "number"
  }
}

Best Practices

  1. Always include fouling factors appropriate for the service
  2. Verify pressure drop constraints are met on both sides
  3. Check for vibration potential in shell-and-tube designs
  4. Consider maintenance access in configuration selection
  5. Apply TEMA tolerances for manufacturing variations
  6. Use conservative correlations for preliminary sizing

Integration Points

  • Connects with CFD Analysis for detailed flow distribution
  • Feeds into HVAC System Design for system integration
  • Supports Thermal Analysis for component-level design
  • Integrates with Process Design for plant-level optimization

Expand your agent's capabilities with these related and highly-rated skills.

a5c-ai/babysitter

gsd-tools

Central utility skill for GSD operations. Provides config parsing, slug generation, timestamps, path operations, and orchestrates calls to other specialized skills. Acts as the unified entry point that the original gsd-tools.cjs provided via its lib/ modules (commands, config, core, init).

514 31
Explore
a5c-ai/babysitter

model-profile-resolution

Resolve model profile (quality/balanced/budget) at orchestration start and map agents to specific models. Enables cost/quality tradeoffs by selecting appropriate AI models for each agent role.

514 31
Explore
a5c-ai/babysitter

verification-suite

Plan structure validation, phase completeness checks, reference integrity verification, and artifact existence confirmation. Provides the structured verification layer ensuring GSD artifacts are well-formed and complete.

514 31
Explore
a5c-ai/babysitter

state-management

STATE.md reading, writing, and field-level updates. Provides cross-session state persistence via .planning/STATE.md with structured fields for current task, completed phases, blockers, decisions, and quick tasks.

514 31
Explore
a5c-ai/babysitter

git-integration

Git commit patterns, formats, and conventions for GSD methodology. Provides atomic commits per task, structured commit messages, planning file commits, branch management, and milestone tag operations.

514 31
Explore
a5c-ai/babysitter

frontmatter-parsing

YAML frontmatter parsing and manipulation for .planning/ documents. Provides read, write, update, query, and validation operations on frontmatter blocks in GSD markdown artifacts.

514 31
Explore

Didn't find tool you were looking for?

Be as detailed as possible for better results